How to Sync or Unsync Split King Adjustable Beds: One Remote, Two Remotes, and Model-Specific Fixes
Need your split king bases to move together or separately? Find manufacturer-specific sync, unsync, remote, and cable instructions.
Sources last checked November 20, 2026.
If both sides of your split king adjustable bed move when you press one remote, but you want each side to work independently, you need to undo the correct type of synchronization for your particular base.
And if you're trying to make both sides move together, the process depends on the model.
Some adjustable beds use a wireless command from their remotes. Others require a synchronization cable between their control systems. Certain models use both a cable and a remote command.
There's no universal button combination that works across every split king bed.
Before changing anything, identify your adjustable-base model and use the matching instructions below.
Jump to a section
First, what are you trying to do?
On a small screen, swipe the table sideways.
| Your goal | What you need |
|---|---|
| One remote should raise both sides | Synchronize compatible bases using the manufacturer's approved method |
| Each remote should control its own side | Restore independent operation or individual remote assignments |
| Both remotes should raise both sides | Verify that your model supports two active remotes while synchronized |
| One remote stopped responding | Troubleshoot remote-to-base pairing, not necessarily base synchronization |
| Both bases should move together but one is lagging | Check the manufacturer's realignment and synchronization troubleshooting |
| Your standard King moves like a split king | Verify the intended King configuration before changing settings |
The most important distinction is between pairing a remote and synchronizing two bases.
Pairing tells a base which remote to recognize.
Synchronization makes two compatible bases respond together to movement commands.
A remote paired successfully with one base does not automatically synchronize two bases.
Find your manufacturer and model
On a small screen, swipe the table sideways.
| Manufacturer and model | How the bases synchronize | Returning to independent control | Remote behavior | Official source |
|---|---|---|---|---|
| TEMPUR-Ergo, models covered by the manufacturer's wireless Sync-button guide | Sync buttons on both remotes | Hold Remote A's Sync button until it blinks | Both remotes participate in setup; follow exact model instructions | TEMPUR-Ergo guide |
| TEMPUR-ActiveBreeze ProSmart Air Base | Sync buttons beneath both remote battery covers | Left remote's Sync button, confirmed by a Disconnected announcement | Motion and fan-control settings are separate considerations | Sync / Unsync |
| Sven & Son Model C2, 2025 manual | Supplied sync cable between control boxes | Return to separate remote assignments, with the cable omitted from independent setup | Both remotes documented as usable when linked | Model C2 manual |
| Sven & Son Model P, 2024 manual | Wireless remote pairing or an optional sync cable | Re-pair each remote with its assigned base following the exact manual | Wireless setup leaves one active remote; cable can support dual controls | Model P manual |
| GhostBed Smart Adjustable Base, manual reviewed | Sync cable plus a five-second FLAT command | Another five-second FLAT command | One remote confirmed; manual has conflicting wording about both remotes | Smart manual |
| GhostBed Power Adjustable Base, U.S. manual edition reviewed | Supplied sync cable between the two control boxes | Independent setup omits the optional cable; verify the exact manual before changing an existing installation | This manual states either remote operates the synchronized bases | Power Base manual |
| Sleep Number Adjustable Base with Remote, sold 2026 or later | Split King is normally independent; standard King/California King uses a sync cable | Follow the Split King configuration and model-specific troubleshooting | Do not treat standard King instructions as Split King sync instructions | Sleep Number setup |
| Innova R8, R8E, R8Z | Manufacturer's remote pairing and optional remote cloning procedure | Unclone and, when necessary, change frequencies and pair one remote to each base | Supports a master remote and cloned second remote for linked bases beneath one King mattress | Innova R8 guide |
Do not use the table as permission to try a procedure on a different model. Match the actual base, manual generation, remote controls, and cable arrangement.
1. TEMPUR-Ergo: Sync two bases wirelessly
Tempur-Pedic publishes a wireless synchronization procedure for compatible TEMPUR-Ergo power bases.
The manufacturer's first requirement is that each remote already be paired with its corresponding control box.
If that hasn't been done, complete the correct individual pairing procedure before attempting synchronization.
To make the bases move together
- Disconnect the bases from power.
- Wait one minute.
- Restore power.
- Find the SYNC button on the back of each remote.
- Press and hold both Sync buttons simultaneously.
- Wait for their lights to flash and then stop flashing.
- Release the buttons.
- Test normal head and foot movement.
If the bases respond but their mechanical positions no longer match, Tempur-Pedic says pressing FLAT can bring the positions back into alignment.
This is not permission to force a bed that's physically obstructed.
To restore independent movement
For the models covered by this support procedure:
- Locate Remote A.
- Press and hold its Sync button.
- Release when the button light blinks.
- Test Remote A on Base A.
- Operate Remote B and verify that it returns to controlling Base B.
Tempur-Pedic explains that Remote B resumes individual communication when it is used after unsynchronization.
Official instructions:
How to sync two TEMPUR-Ergo power bases
If your remote does not have the specified Sync button, don't substitute an older Ergo Premier RF-channel procedure.
Different generations use different systems.
2. TEMPUR-ActiveBreeze: The bases and fans have separate settings
TEMPUR-ActiveBreeze ProSmart Air bases have a documented synchronization system.
The Sync buttons are located behind the battery covers on the remotes.
Synchronizing the bases
Press and hold the Sync button on both remotes simultaneously.
The buttons illuminate and flash.
When flashing stops, release them.
The speakers on both bases announce Connected when synchronization succeeds.
The bases can then move together.
Unsynchronizing the bases
If the bases are linked and you want separate movement:
- Open the battery cover on the remote assigned to the left-side base.
- Press and hold the Sync button.
- Release it when the button light blinks.
- Listen for the Disconnected confirmation.
- Verify that each remote operates its own side.
Those are the instructions documented for the ActiveBreeze system. They should not automatically be transferred to every Tempur-Pedic base.
What about the cooling and warming fans?
This is an additional distinction.
Tempur-Pedic allows a synchronized ActiveBreeze setup to have independently controlled fans through Split Fan Mode.
For the documented ProSmart Air setup, the left-side remote can enable the mode by holding the Left Warming and Sync Cooling buttons together for six seconds.
The remote backlight flashes twice to confirm the mode change.
That is a fan-control setting, not the same thing as restoring independent mattress movement.
If one side's fans respond unexpectedly after the bases are synchronized, investigate Split Fan Mode separately.
Manufacturer references:
3. Sven & Son: Your exact manual makes a difference
Sven & Son is a good example of why a brand name alone isn't enough.
An older manufacturer guide explains wireless synchronization using a blue pairing button.
Other official manuals describe cable-based synchronization.
The difference can affect whether one or both remotes remain usable.
Sven & Son Model C2: Sync cable with both remotes
The official 2025 Model C2 manual documents a physical sync cable.
The manual's independent-operation instructions begin with Remote A controlling Base A and Remote B controlling Base B.
For synchronized operation, it instructs owners to connect the appropriate sync cable to the Sync Cable Input on each base's control box.
Both remotes should then operate the synchronized system.
This matters if you want a remote on each nightstand.
To return to independent operation: The manual describes independent use with each remote assigned to its own base and the sync cable not part of that configuration.
If the cable is currently installed, disconnect power before accessing the connections and follow the manual's safety instructions for handling them.
After returning to the independent configuration, test each remote separately.
If the remotes do not resume their original assignments, follow Model C2's individual remote-pairing instructions rather than assuming the cable change alone restores everything.
The Model C2 pairing procedure uses the head-up and foot-up buttons together with the sync button on the specified power-supply cord. The manual identifies three beeps as successful pairing.
Official source:
Sven & Son Model C2 manual, pages 5 and 8–9
Sven & Son Model P: Wireless linking or cable synchronization
The Model P manual documents two approaches.
Wireless method:
First, confirm that each remote controls its own base.
Then pair Remote A with Base B using the Model P pairing procedure.
After successful pairing, Remote A can operate both bases.
The manual explicitly says Remote B will no longer function in this arrangement.
Cable method:
The manufacturer also documents a sync cable connected to the supported input on each control box.
The manual describes it as an alternative that supports dual controls.
Those are different ways of linking the bases.
How do you unsync a Sven & Son system?
Use the instructions matching your particular remote and base.
For the blue inline pairing-button system described in Sven & Son's help center, the manufacturer gives an independent-control recovery procedure:
- Disconnect both bases from power and remove batteries from both remotes.
- Work with one side at a time.
- Hold that remote's head-up and foot-up buttons while reinserting its batteries.
- Reconnect the matching base to power.
- Use the specified blue pairing button together with head-up and foot-up.
- Listen for the manufacturer's confirmation beep.
- Verify the remote controls only the intended base.
- Repeat for the other base.
Do not use that recovery sequence unless your equipment matches the documented control arrangement.
For Model P hardware with pairing controls in different locations, use its own manual.
And if the two bases are joined through a sync cable, first verify the instructions for disconnecting that exact cable.
Manufacturer sources:
4. GhostBed Smart: Cable connection plus the FLAT button
The GhostBed Smart Adjustable Base has a particularly important two-part procedure.
Simply installing the cable is not the entire documented setup.
Synchronizing two compatible Smart bases
The manufacturer's manual specifies:
- Connect the supplied sync cable between the green splitter cables on the two bases, using the exact illustrated connections.
- Press and hold the FLAT button on one remote for five seconds.
- Watch for three backlight flashes.
- Allow the bases to complete their automatic leveling operation.
- Do not press other buttons during that process.
Once synchronization finishes, the bases should respond together.
This process is specific to the GhostBed Smart manual reviewed.
Don't plug the cable into a different connector because it looks physically similar.
Disabling synchronization
The same manual gives a direct reversal command.
Press and hold FLAT again for five seconds.
The backlight should flash three times and turn off.
That is the manufacturer's documented method for disabling synchronization on this Smart system.
Will both Smart remotes still work?
There is an unresolved wording difference in the manual.
The synchronization instructions on printed page 9 state that one remote controls the linked bases.
A later configuration chart on printed page 13 says both remotes may be used.
These statements are not sufficiently consistent to guarantee dual-remote behavior for every configuration.
If you specifically need both remotes to control the combined bed, ask GhostBed to clarify which procedure and remote arrangement apply to your exact Smart Adjustable Base.
Official source:
GhostBed Smart Adjustable Base owner's manual, pages 9 and 13
5. GhostBed Power Adjustable Base: A different cable procedure
GhostBed has also published manuals for its Power Adjustable Base.
One official U.S. edition documents this process for two Twin XL bases:
- Unplug both bases.
- Connect the manufacturer's synchronization cable to the two designated control boxes.
- Restore power.
- Test the linked bases.
This particular manual says both bases respond together to either remote.
Its independent-setup note says the sync cable isn't needed when the user does not want the bases linked.
If you already have a working synchronized Power Base arrangement and want to separate it, identify the correct manual, disconnect power as instructed, and confirm the appropriate cable and remote assignments before making changes.
The reviewed U.S. manual does not provide a separate, comprehensive post-installation re-pairing sequence specifically for reversing an existing linked setup.
Contact GhostBed if removing the optional link according to the applicable manual does not restore independent operation.
Official manual:
6. Sleep Number: A Split King isn't supposed to act like a standard King
This is one of the most important exceptions.
Sleep Number's support documentation dated October 20, 2026 covers Adjustable Bases with Remote sold in 2026 or later.
It distinguishes the intended movement of different configurations.
Standard Eastern King and California King: Both sides are designed to move together.
Split King: Each side is designed to move independently.
The accompanying installation guide instructs owners not to connect the sync cable for a Split King. That cable is used for the supported standard King and California King configurations.
So if you have this Sleep Number Split King system, don't follow the standard King sync-cable instructions simply because you want both mattresses to rise together.
Ask Sleep Number whether any alternative behavior is supported for your exact configuration.
What if your Sleep Number setup is behaving incorrectly?
The manufacturer's initial reset procedure is:
- Return the base to flat using the remote, if normal operation permits.
- Disconnect power to both sides.
- Wait 30 seconds.
- Restore power.
- Test the expected operation.
For a Split King, that means testing independent movement.
If the problem continues, Sleep Number provides additional steps to inspect the applicable installation and connections.
Those later steps require two people and may involve mattress removal and repositioning the base for access.
Don't crawl beneath a powered frame or attempt that work alone.
Owners with air-chamber mattresses must also follow the manufacturer-specific instructions for hoses and air-chamber caps.
If the problem persists, contact Sleep Number.
These October 2026 instructions should not be applied automatically to earlier FlexFit systems or unrelated Sleep Number bases.
Sources:
7. Innova R8, R8E, and R8Z: Pairing, cloning, and uncloning
Innova Sleep Systems publishes another useful example.
Its R8/R8E/R8Z support guide separates the following operations:
- Pairing a remote with a base.
- Making a master remote control both bases.
- Cloning a secondary remote.
- Uncloning the secondary remote.
- Fully returning to separate control.
That distinction is important.
Making both remotes operate the combined bed
Innova documents this shared-remote setup for two bases under a single King mattress. For two Twin XL mattresses that should move independently, its guide assigns one remote to each base.
After pairing the master remote with both bases, use the R8-family cloning procedure. Hold the secondary remote buttons first, then hold the master remote buttons while the secondary flashlight is on:
- Head Down and Foot Down on the secondary remote.
- Head Up and Foot Up on the master remote.
The secondary remote's flashlight indicates successful copying.
Afterward, both remotes can control both bases.
Returning to separate operation
Simply uncloning the secondary remote isn't necessarily the entire reversal.
Innova distinguishes uncloning from fully disconnecting the remotes.
Its R8/R8E/R8Z guide directs owners to change the relevant remote frequencies and pair each remote with its corresponding base to restore fully separate communication.
The manufacturer also provides different frequency-change instructions based on the remote's production year.
That is why we would not publish one generic Richmat reset sequence.
Follow the exact R8-family guide and confirm your remote generation before changing frequencies.
Official instructions:
What if one remote controls both bases and you want two independent sides?
First, stop using that remote to make adjustments that your partner doesn't want.
Then work through this short decision:
Does your base use a sync cable?
Check the documentation for your exact model. If it does, determine whether the cable is intended for the synchronized configuration or required for some other function.
Don't disconnect unknown cables.
Does your remote have a dedicated Sync button?
Check the manufacturer's instructions for that control.
On supported TEMPUR-Ergo systems, there is a documented way to reverse wireless synchronization.
Did you previously pair one remote with both bases?
You may need to restore one-to-one pairing.
Sven & Son and Innova document model-specific approaches to that problem.
Are you using a Sleep Number 2026 Split King?
The expected configuration is independent operation. Follow Sleep Number's instructions rather than another manufacturer's remote-pairing procedure.
If you cannot identify the control system, contact the base manufacturer with the model number and a photograph of the remote.
What if both remotes control both sides?
This is not automatically a malfunction.
Some synchronized systems intentionally allow both remotes to operate the linked foundations.
Sven & Son Model C2 and the reviewed GhostBed Power manual provide examples.
Other systems may leave one active remote.
If your goal is separate control, don't assume that switching off one remote will solve it.
You need to undo the linking or remote-assignment method documented for your model.
What if only one adjustable base responds?
A failed remote or disconnected base can look like a synchronization problem.
Before trying to re-pair everything:
Check both bases have power. A base that isn't receiving power cannot respond properly.
Check the remote batteries. Follow the manufacturer's battery instructions.
Check for child lock. Some systems, including the GhostBed Smart and Innova R8 family, have child-lock conditions that can prevent ordinary movement.
Check for obstructions. Look around the frames, headboard, foot, and accessible surrounding area.
Check the manufacturer's specified connection. On a cable-linked system, a damaged or disconnected sync cable may explain why the sides stopped operating together.
Do not diagnose a failed motor or control box simply because a remote isn't working.
If both sides work separately but not together, that is different from one side being completely unresponsive.
Describe that distinction when contacting support.
Can two different adjustable-base brands be synchronized?
Don't assume so.
The reviewed manufacturer instructions describe supported bases and their specified control systems.
We found no evidence establishing universal interoperability between unrelated adjustable-base brands, remote systems, or sync cables.
Even two products sold by the same brand may use different generations of electronics.
A cable that physically fits a connector is not proof of compatibility.
Ask the manufacturers before attempting to link mixed models.
A split king is not always the same as a standard king or split-head bed
The terminology can be confusing.
A true split king generally uses two independently adjustable Twin XL sleeping surfaces.
A standard King configuration may use a pair of linked foundations that are intended to move as one unit beneath a single mattress.
A split-head design can have yet another arrangement, with separate head movement but shared movement elsewhere.
The control behavior depends on the actual base and mattress configuration, not merely on the combined bed width.
If you're distinguishing a standard King from a true split king or a partially split configuration, our Saatva Split King vs. King guide explains the physical differences.
But for synchronization instructions, the adjustable-base model remains the deciding factor.
When should you stop troubleshooting?
Stop and contact the manufacturer if:
- You cannot identify the exact remote or base model.
- The available manual doesn't match your control arrangement.
- A required sync cable is missing or visibly damaged.
- A base moves unexpectedly or doesn't stop normally.
- The two frames bind against each other.
- A powered component, cable, or control box appears damaged.
- The bases remain out of sync after the documented procedure.
- An official instruction requires under-bed access you cannot perform safely.
Never open electrical control boxes, modify wiring, bypass safeguards, or connect improvised synchronization cables.
Before accessing the underside of a base, follow its exact manual for power disconnection and safe positioning. Heavy bases may require two people.
Keep children, pets, loose objects, and limbs clear of moving mechanisms.
What to tell the manufacturer
Have the following ready:
- Adjustable-base brand and exact model.
- Remote model or photograph.
- Approximate purchase year.
- Whether the system has one or two mattresses.
- Whether each base works independently.
- Whether a sync cable is currently installed.
- Whether you want one remote or two.
- What happened immediately before the problem started.
These details help the manufacturer identify the right instructions without guessing.
Frequently asked questions
How do I make one remote control both sides of my split king bed?
Use the synchronization method supported by your exact base.
That might involve remote programming, a specified sync cable, or both.
Not every model supports that configuration.
How do I unsync a split king adjustable bed?
The answer depends on how it was synchronized.
TEMPUR-Ergo and GhostBed Smart document specific reversal commands. Some cable-based systems require returning to their independent wiring and remote assignments.
Follow the manufacturer's exact instructions.
Will both remotes still work after synchronization?
Sometimes.
Sven & Son Model C2 documents both remotes controlling a cable-linked system.
Sven & Son Model P's wireless method instead makes Remote A the active control and disables Remote B.
Do not assume one behavior is universal.
Why did both sides suddenly start moving together?
Possible explanations include a remote linked to both bases, an unexpected control configuration, or a change in the system's synchronization setup.
Check the actual configuration before diagnosing an internal failure.
Can I synchronize two bases without a cable?
Some supported models allow wireless synchronization.
TEMPUR-Ergo and certain Sven & Son configurations are documented examples.
Other systems require a cable.
Should I reset both remotes?
Not automatically.
A remote reset may address pairing but doesn't necessarily reverse base synchronization.
Changing frequencies without following the model's procedure can create another problem.
Can synchronized beds still have separate massage or fan controls?
That depends on the system.
TEMPUR-ActiveBreeze documents Split Fan Mode, allowing separate fan control in an otherwise synchronized setup.
Do not assume that an unrelated base supports the same feature.
Before changing the setup
The safest way to solve a split king synchronization problem is to identify the exact control system first.
Look for the manufacturer and base model, compare the remote to its official manual, and determine whether the system uses a cable, wireless pairing, or both.
Then use the procedure for the result you actually want.
If you need each remote to control its own side, restoring independent operation is a different task from merely re-pairing an unresponsive remote.
And if you want both remotes to control both sides, verify that the manufacturer supports that arrangement before changing anything.
Sources & research notes
Sources checked November 20, 2026.
- TEMPUR-Ergo wireless synchronization (opens in new tab)
- TEMPUR-ActiveBreeze ProSmart Air synchronization (opens in new tab)
- TEMPUR-ActiveBreeze independent operation (opens in new tab)
- TEMPUR-ActiveBreeze Split Fan Mode (opens in new tab)
- Sven & Son Model C2 owner's manual (opens in new tab)
- Sven & Son Model P owner's manual (opens in new tab)
- Sven & Son general remote help (opens in new tab)
- GhostBed Smart Adjustable Base manual (opens in new tab)
- GhostBed Power Adjustable Base, U.S. manual (opens in new tab)
- Sleep Number Adjustable Base Assembly and Disassembly (opens in new tab)
- Sleep Number: King Base Out of Sync (opens in new tab)
- Innova R8/R8E/R8Z troubleshooting (opens in new tab)
- Leesa Split King sync FAQ (opens in new tab)